Eliwell Sb655 C Manual May 2026
| Alarm Code | Meaning | Likely Cause & Solution | | :--- | :--- | :--- | | | Internal EEPROM error | Faulty controller; replace unit. | | E1 | Probe 1 faulty (open circuit) | Broken probe, loose wire at terminals 2/3, or wrong S1P setting. | | E2 | Probe 1 short circuit | Moisture in probe tip, damaged probe, or short across terminals 2-3. | | HA | High temperature alarm | Temperature above ALU (alarm upper limit). Check compressor, refrigerant, fans. | | LA | Low temperature alarm | Temperature below ALL (alarm lower limit). Check setpoint, probe placement. | | PFA | Probe failure alarm – output forced | Controller is running a timed cycle because E1/E2 is active. Check probe wiring. |
This guide is for informational purposes. Always consult the original manufacturer’s documentation specific to your unit’s revision before performing electrical work. eliwell sb655 c manual
A: ELIWELL NTC 10kΩ at 25°C (probe type: NTC103AT) is standard. PTC probes (PtC) are also supported if you change parameter S1P to “PtC.” Do not use PT100 (RTD) probes; they are incompatible. 10. Conclusion The Eliwell SB655 C is a workhorse of the refrigeration industry. Whether you are building a new cold room or repairing a frozen display case, understanding its manual is key to a long, trouble-free service life. | Alarm Code | Meaning | Likely Cause